MICROBIAL AIR SAMPLERS FOR ISOLATORS AND RABS

EXPECT NOTHING

MAS-100 ISO

AIR. NOTHING ELSE.

MAS-100 Iso microbial air samplers were specially designed for air monitoring in isolators and RABS. Every detail has been perfected over the years together with established pharmaceutical companies and containment manufacturers. Simple integration, decontamination and calibration are just as important as the complete documentation and precision of microbial air samplers.

MAS-100 ISO. WINS OVER.
  • Hygienic design and perfect workmanship
  • Maximum protection for the product and environment
  • 100% compliant with all regulations
  • Durable and fail-safe in routine production
  • Space-saving and suitable for all isolators and RABS

WHEN MAXIMUM SAFETY COUNTS

All moving parts of MAS-100 Iso microbial air samplers are located outside the containment to minimise the risk of contamination inside the containment. All internal elements are made of high quality stainless steel. They can be easily cleaned and decontaminated with gaseous or vaporized hydrogen peroxide (H2O2).






FLEXIBILITY & COMFORT

  • MAS-100 Iso base unit with blower, air flow sensor, valves and components
  • Contamination-free maintenance thanks to installation outside the critical zone
  • Status information can be exchanged in real-time with the isolator control system

HIGHEST SAMPLING EFFICIENCY & LONG-TERM STABILITY

  • Precision-machined stainless steel perforated lids for optimal measurement results
  • Available in various designs for utmost operating comfort – e. g. perforated lids with handle for hard-to-reach places






EFFECTIVE & SAFE

Pipe/hose system connects the MAS-100 Iso base unit outside the containment with the sampling head inside the enclosure

MAXIMUM CONTAMINATION PROTECTION

Extra protection thanks to the double valve system of the base unit

ADDITIONAL PROTECTION

Optional HEPA filter protects equally employees and the environment from exposure to highly active substances






SMART SOPHISTICATED

EasyClean plate holder for vertical airflow is easy to clean and to decontaminate with aqueous and vaporized hydrogen peroxide

EASY TO CLEAN

Sampling head with standard perforated lid and plate holder. The seal without a sealing ring provides easy cleaning

COMPLIANT AIR SAMPLING

A flow sensor within the MAS-100 Iso calibrated with the certified MAS-100 Regulus ensures that the correct amount of air is always sampled.

Any questions?

Our expert Andy Zingre will be happy to assist you with a non-binding and free consultation. We look forward to hearing from you.


    +41 44 928 30 80
   andy.zingre@mbv.ch

Send inquiry

Schedule online meeting
MH OR NT. RIGHT EITHER WAY.












MAS-100 ISO NT

The MAS-100 Iso NT is equipped with one sampling head. The active air sampler can be conveniently operated via the integrated touch display or one of the data interfaces.

Learn moreSend request

MAS-100 ISO MH

The MAS 100 Iso MH microbial air sampler is the newest microbial air sampler of the MAS-100 Iso product family. A base unit can accommodate up to four sampling heads.

Learn moreSend request











PERFECTION CAN BE SO SIMPLE.


Highest Quality Standard
The microbial air samplers are manufactured from high-quality, particle-free components in accordance with the highest Swiss quality criteria. All parts are manufactured and assembled with utmost care and attention to detail. They guarantee long-lasting, trouble-free operation.

Simple Software Integration
MAS-100 Iso microbial air samplers win over not only because of their excellent hardware, but also because of simple software integration into higher-level control systems.

Comprehensive documentation
All control functions can be automated with complete documentation. We also provide CAD drawings. Thus, the integration of your microbial air sampler in the isolator can be perfectly planned.

CALIBRATION

The air flow of a microbial air sampler influences the collection efficiency and thus the microbial measurement result. Therefore, the air flow should be professionally verified annually. For the calibration of MAS-100 Iso air samplers we offer three flexible solutions:

  1. Send your air sampler to our service center in Switzerland.
  2. Our service engineer or a certified service partner will calibrate the instrument at your site.
  3. Calibrate your instrument independently using the MAS-100 Regulus® digital anemometer.

In any case, we ensure that the calibration of your air sampler can be traced back to international standards via the certified MAS-100 Regulus digital anemometer and via our ISO 17025 accredited calibration laboratory.

MBV SERVICES

SERVICE, SUPPORT, CALIBRATION AND REPAIR FROM MBV HEADQUARTERS

MAS-100 air samplers are robust and durable. But even the very best products need the best service to guarantee that they work optimally and reliably at all times. Whether it is a matter of calibration, adjustment, application support or repair, high quality and your satisfaction are always our top priority.

Read more »

From experts to experts

Downloads

BROSCHÜRE

"EXPECT NOTHING" - Everything you need to know about the MAS-100 Iso air sampler

Download »

FACTSHEET

Air sampler
MAS-100 Iso MH

Download »

FACTSHEET

Air sampler
MAS-100 Iso NT

Download »

EXPERT VIEW

Our CEO Ronny Zingre in the EPR – about active air monitoring in aseptic fill/finish isolators

Download »

SATISFIED CUSTOMERS

These “integrator” companies already successfully rely on our innovative products. They benefit from perfect Swiss quality, easy handling and reliable safety, all of which collectively make all the difference.

MBV NEWSLET­TER

Don't miss out!

Get the latest microbiology air monitoring updates quarterly.